Clinical Impact of Persistent Left Bundle-Branch Block After Transcatheter Aortic Valve Implantation With CoreValve Revalving System.

Articolo
Data di Pubblicazione:
2013
Abstract:
Background—Conduction disturbances are relatively common after transcatheter aortic valve implantation. Previous data demonstrated an adverse impact of persistent left bundle-branch block (LBBB) after surgical aortic valve replacement. It is unclear whether new-onset LBBB may also impact the prognosis of patients after transcatheter aortic valve implantation.
Methods and Results—Among 1060 patients treated with a CoreValve Revalving System transcatheter aortic valve implantation between October 2007 and April 2011 in high-volume centers in Italy, we analyzed those without LBBB or pacemaker at admission (879 patients [82.9%]). We further excluded those who underwent permanent pacemaker implantation within 48 hours after the procedure (61 patients [7%]), for a final study population of 818 patients. Among them, 224 patients (group A; 27.4%) developed a persistent LBBB and the remaining 594 (group B; 72.6%) did not. Clinical characteristics were similar between groups. A low implantation was significantly more frequent in group A (15% versus 9.8%, P=0.02). No patients were censored before 1 year (median follow-up period 438 days, interquartile range 174–798 days). Survival analyses and inherent log-rank tests showed that LBBB was not associated with higher all-cause mortality, cardiac mortality, or hospitalization for heart failure at 30 days or 1 year. At 30 days, but not at 1 year, group A had a significantly higher rate of pacemaker implantation.
Conclusions—In this registry of high-volume centers, persistent LBBB after CoreValve Revalving System transcatheter aortic valve implantation showed no effect on hard end points. On the other hand, LBBB was associated with a higher short-term rate of pacemaker implantation.
Tipologia CRIS:
1.1 Articolo in rivista
Elenco autori:
Testa, L; Latib, A; De Marco, F; De Carlo, M; Agnifili, M; Latini, Ra; Petronio, As; Ettori, F; Poli, A; DE SERVI, Stefano; Ramondo, A; Napodano, M; Klugmann, S; Ussia, Gp; Tamburino, C; Brambilla, N; Colombo, A; Bedogni, F.
Autori di Ateneo:
DE SERVI STEFANO
Link alla scheda completa:
https://iris.unipv.it/handle/11571/980992
Pubblicato in:
CIRCULATION