Skip to Main Content (Press Enter)

Logo UNIPV
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture

UNIFIND
Logo UNIPV

|

UNIFIND

unipv.it
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture
  1. Pubblicazioni

Effect of light-tip distance on the shear bond strengths of resin-modified glass ionomer cured with high-intensity halogen, light-emitting diode, and plasma arc lights

Articolo
Data di Pubblicazione:
2006
Abstract:
INTRODUCTION: The purpose of this study was to assess the effect of light-tip distance on the shear bond strength and the failure site of brackets cured with 3 light-curing units (high-intensity halogen, light-emitting diode, and plasma arc). METHODS: One hundred thirty-five bovine mandibular permanent incisors were randomly allocated to 9 groups of 15 specimens each. Stainless steel brackets (Victory Series, Unitek/3M, Monrovia, Calif) were bonded with a resin-modified glass-ionomer (Fuji Ortho LC, GC Europe, Leuven, Belgium) to the teeth, and each curing light was tested at 3 distances from the bracket: 0, 3, and 6 mm. After bonding, all samples were stored in distilled water at room temperature for 24 hours and subsequently tested for shear bond strength. RESULTS: When the 3 light-curing units were compared at a light-tip distance of 0mm, they showed no significantly different shear bond strengths. At a light-tip distance of 3 mm, no significant differences were found between the halogen and plasma arc lights, but both lights showed significantly higher shear bond strengths than the light-emitting diode light. At a light-tip distance of 6 mm, no significant differences were found between the halogen and light-emitting diode lights, but both showed significantly lower bond strengths than the plasma arc light. When the effect of the light-tip distance on each light-curing unit was evaluated, the halogen and light-emitting diode lights showed no significant differences among the 3 distances. However, the plasma arc light produced significantly higher shear bond strengths at a greater light-tip distance. No significant differences were found among the adhesive remnant index scores of the various groups, except with the LED light at a distance of 3 mm. CONCLUSIONS: In hard-to-reach areas, the plasma arc curing light is suggested for optimal curing efficiency.
Tipologia CRIS:
1.1 Articolo in rivista
Keywords:
light-tip distance; shear bond strength; failure site
Elenco autori:
Sfondrini, MARIA FRANCESCA; Cacciafesta, Vittorio; Scribante, Andrea; Boeheme, Andreas; Jost Brinkmann Paul, Georg
Autori di Ateneo:
SCRIBANTE ANDREA
SFONDRINI MARIA FRANCESCA
Link alla scheda completa:
https://iris.unipv.it/handle/11571/31427
Pubblicato in:
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS
Journal
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 26.1.3.0