Skip to Main Content (Press Enter)

Logo UNIPV
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture

UNIFIND
Logo UNIPV

|

UNIFIND

unipv.it
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture
  1. Pubblicazioni

Determination of serum holotranscobalamin concentrations with the AxSYM active B12 assay: Cut-off point evaluation in the clinical laboratory

Articolo
Data di Pubblicazione:
2010
Abstract:
Background: A reliable early marker is required for diagnosis of cobalamin deficiency. We calculated an appropriate holotranscobalamin (HoloTC) cut-off point for identifying cobalamin deficiency using an immunoenzymatic assay. Methods: Determination of the cut-off threshold and correlation between HoloTC and the other diagnostic parameters routinely used for vitamin B12 deficiency [total vitamin B12 (tB12), folate, homocysteine] were measured in 250 routine blood specimens from 107 men (mean age 59.0±18.8 years) and 143 women (mean age 54.2±23.1 years). The inclusion criterion was serum tB12 concentration ≤221 pmol/L. Results: Analytical performance results agreed with those reported by others. A weak correlation (R=0.42) was found between HoloTC and tB12. A 40 pmol/L cut-off threshold was chosen for HoloTC and the associated sensitivity and specificity was 0.86 and 0.66, respectively. Out of 250 tested samples, 126 showed tB12 concentrations 139-221 pmol/L (gray zone, GZ) and 124 had tB12 concentrations <139 pmol/L (low, L). Values less than the cut-off for HoloTC were present in 68.2% and 37.9% of cases in the GZ and L group, respectively (p<0.01), and in 53.2% of subjects. Conclusions: Our results confirmed the analytical reliability of the AxSYM HoloTC assay. The method is adequate for routine use and a cut-off threshold of 40 pmol/L is appropriate for assessing cobalamin deficiency in populations with reduced tB12 values. © 2010 by Walter de Gruyter Berlin New York.
Tipologia CRIS:
1.1 Articolo in rivista
Keywords:
Analytical performance; Holotranscobalamin; Immunoenzymatic assay; Vitamin B; 12
Elenco autori:
Bamonti, F.; Moscato, G. A.; Novembrino, C.; Gregori, D.; Novi, C.; De Giuseppe, R.; Galli, C.; Uva, V.; Lonati, S.; Maiavacca, R.
Autori di Ateneo:
DE GIUSEPPE RACHELE
Link alla scheda completa:
https://iris.unipv.it/handle/11571/1342770
Pubblicato in:
CLINICAL CHEMISTRY AND LABORATORY MEDICINE
Journal
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 26.9.2.0