Skip to Main Content (Press Enter)

Logo UNIPV
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture

UNIFIND
Logo UNIPV

|

UNIFIND

unipv.it
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture
  1. Pubblicazioni

Use of dual-flow bioreactor to develop a simplified model of nervous-cardiovascular systems crosstalk: A preliminary assessment

Articolo
Data di Pubblicazione:
2020
Abstract:
Chronic conditions requiring long-term rehabilitation therapies, such as hypertension, stroke, or cancer, involve complex interactions between various systems/organs of the body and mutual influences, thus implicating a multiorgan approach. The dual-flow IVTech Live-Box2 bioreactor is a recently developed inter-connected dynamic cell culture model able to mimic organ crosstalk, since cells belonging to different organs can be connected and grown under flow conditions in a more physiological environment. This study aims to setup for the first time a 2-way connected culture of human neuroblastoma cells, SH-SY5Y, and Human Coronary Artery Smooth Muscle Cells, HCASMC through a dual-flow IVTech Live-Box2 bioreactor, in order to represent a simplified model of nervous-cardiovascular systems crosstalk, possibly relevant for the above-mentioned diseases. The system was tested by treating the cells with 10nM angiotensin II (AngII) inducing PKCβII/HuR/VEGF pathway activation, since AngII and PKCβII/HuR/VEGF pathway are relevant in cardiovascular and neuroscience research. Three different conditions were applied: 1- HCASMC and SH-SY5Y separately seeded in petri dishes (static condition); 2- the two cell lines separately seeded under flow (dynamic condition); 3- the two lines, seeded in dynamic conditions, connected, each maintaining its own medium, with a membrane as interface for biohumoral changes between the two mediums, and then treated. We detected that only in condition 3 there was a synergic AngII-dependent VEGF production in SH-SY5Y cells coupled to an AngII-dependent PKCβII/HuR/VEGF pathway activation in HCASMC, consistent with the observed physiological response in vivo. HCASMC response to AngII seems therefore to be generated by/derived from the reciprocal cell crosstalk under the dynamic inter-connection ensured by the dual flow LiveBox 2 bioreactor. This system can represent a useful tool for studying the crosstalk between organs, helpful for instance in rehabilitation research or when investigating chronic diseases; further, it offers the advantageous opportunity of cultivating each cell line in its own medium, thus mimicking, at least in part, distinct tissue milieu.
Tipologia CRIS:
1.1 Articolo in rivista
Keywords:
Replacement-Reduction-Refinement (3R's), Cell Crosstalk, Dual-flow Bioreactor, Millifluidic System, Inter-Connected Dynamic Cell Culture Model, Pre-clinical Models
Elenco autori:
Marchesi, N.; Barbieri, A.; Fahmideh, F.; Govoni, S.; Ghidoni, A.; Parati, G.; Vanoli, E.; Pascale, A.; Calvillo, L.
Autori di Ateneo:
BARBIERI ANNALISA
GOVONI STEFANO
MARCHESI NICOLETTA
PASCALE ALESSIA ANGELA
Link alla scheda completa:
https://iris.unipv.it/handle/11571/1366734
Pubblicato in:
PLOS ONE
Journal
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 25.11.5.0