Skip to Main Content (Press Enter)

Logo UNIPV
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture

UNIFIND
Logo UNIPV

|

UNIFIND

unipv.it
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture
  1. Pubblicazioni

Effect of Collar Diameter and Simulated Aging on the Orthogonal Load Resistance of Orthodontic Miniscrews

Articolo
Data di Pubblicazione:
2026
Abstract:
The use of miniscrews as Temporary Skeletal Anchorage Devices (TSAD) in orthodontics has allowed clinicians to perform challenging tooth movements by dissipating undesired forces into the bone structure; thus, avoiding unwanted movement of the adjacent teeth. It is essential for miniscrews to be highly resistant to fracture during clinical use. While many studies have analysed torsional loads, none have measured the changes in flexural and bending strength of miniscrews before and after an ageing process. This study aims to analyse the resistance to orthogonal forces of miniscrews with different diameters, focusing on both new and aged materials, the latter subjected to thermocycling and autoclaving laboratory processes to simulate a 3- and a 6-month exposure to the oral environment. A total of 105 pristine miniscrews have been tested; specimens were divided into seven groups based on the different endosseous body diameters. Each group was further subdivided into three subgroups, according to the simulated ageing of the miniscrews (intact, 3 months of ageing and 6 months of ageing, respectively). An Instron Universal Testing Machine has been used to measure deflection at 0.1 mm and 0.2 mm, as well as maximum load at fracture. The results evidenced that miniscrews respond differently to cutting forces; in particular, the resistance to orthogonal loads increases as the diameter of the miniscrews increases. Linear regression analysis revealed a significant influence between all the dependent variables—maximum load, 0.1 mm deflection load, and 0.2 mm deflection load—and the independent variables, such as diameter and thermocycling (p < 0.05). Both new and aged miniscrews are suitable for orthodontic and orthopaedic loads; moreover, ageing up to 6 months does not seem to significantly decrease the resistance to shear forces for the same diameter. Linear regression analysis of the miniscrews subjected to experimental ageing showed a slight but significant decrease in resistance to orthogonal loading.
Tipologia CRIS:
1.1 Articolo in rivista
Keywords:
autoclaving; diameter; fracture; miniscrew; orthodontics; thermocycling
Elenco autori:
Sfondrini, M. F.; Merlati, G.; Pascadopoli, M.; Valceschini, L.; Ricchio, S.; Torchia, M. M.; Del Corso, L.; Scribante, A.
Autori di Ateneo:
MERLATI GIUSEPPE
PASCADOPOLI MAURIZIO
SCRIBANTE ANDREA
SFONDRINI MARIA FRANCESCA
VALCESCHINI LETIZIA
Link alla scheda completa:
https://iris.unipv.it/handle/11571/1542715
Pubblicato in:
MATERIALS
Journal
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 26.1.3.0