The design and tests of Timing Counter elements for the upgrade of the MEG experiment, MEG II, are presented. The detector is based on several small plates of scintillator with a Silicon
PhotoMultipliers dual-side readout. The optimisation of the single counter elements (SiPMs, scintillators, geometry) is described. Moreover, the results obtained with a first prototype tested at the Beam Test Facility (BTF) of the INFN Laboratori Nazionali di Frascati (LNF) are presented.
PhotoMultipliers dual-side readout. The optimisation of the single counter elements (SiPMs, scintillators, geometry) is described. Moreover, the results obtained with a first prototype tested at the Beam Test Facility (BTF) of the INFN Laboratori Nazionali di Frascati (LNF) are presented.
Tipologia CRIS:
1.1 Articolo in rivista
Keywords:
Scintillators; Photon detectors for UV, visible and IR photons; scintillation and light emission processe
Elenco autori:
Cattaneo, P; M., De Gerone; F., Gatti; W., Ootani; Y., Uchiyama; M., Nishimura; S. Shirabe And M., Rossella