Skip to Main Content (Press Enter)

Logo UNIPV
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture

UNIFIND
Logo UNIPV

|

UNIFIND

unipv.it
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture
  1. Pubblicazioni

Pentacam sensitivity and specificity in detecting occludable angles.

Articolo
Data di Pubblicazione:
2012
Abstract:
Purpose. To assess the sensitivity and specificity of Pentacam measurements in detection of occludable angles and to provide cutoff values. Methods. Observational, single-center, cross-sectional study on 64 Caucasian eyes: 28 (43.7\%) primary narrow angles or primary angle-closure glaucoma, and 36 (56.2\%) controls: all subjects were evaluated and classified by gonioscopy (Shaffer classification). The following measurements have been considered: superior and inferior anterior chamber angle (ACA), temporal and nasal ACA, anterior chamber depth (ACD) using 5 value representation (central, superior, inferior, nasal, temporal), and anterior chamber volume (ACV). Validity of Pentacam parameters to detect patients in Shaffer 0 or I class was assessed by receiver operating characteristic (ROC) curves analysis; cutoffs were chosen as to maximize sensitivity and specificity. Results. All the considered Pentacam measures were statistically different between the 2 groups (p<0.0001). All Shaffer grade groups differed in all parameters (p<0.001), except for grade 0 and I, which did not differ in any. Area under the curve ROC analysis revealed high discriminant power of all Pentacam measures: ACA = 0.94; ACD = 0.91; ACD central = 0.89; and ACV = 0.89. Chosen cutoff values (ACA = 22.4°; ACD = 1.12 mm; ACD central = 1.93 mm; ACV = 84 mm3) allowed correct classification of narrow angles. Conclusions. The study pointed out a high power of Pentacam AVA, ACV, and ACD in detecting occludable angles. Pentacam is simple to use, reliable, and noncontact, provides parameters in a short period, and represents a possible screening tool.
Tipologia CRIS:
1.1 Articolo in rivista
Elenco autori:
Rossi, Gcm; Scudeller, L; Delfino, Alessio; Raimondi, Marta; Pezzotta, Sara; Maccarone, M.; Antoniazzi, E; Pasinetti, Gm; Bianchi, PAOLO EMILIO
Autori di Ateneo:
BIANCHI PAOLO EMILIO
Link alla scheda completa:
https://iris.unipv.it/handle/11571/438287
Pubblicato in:
EUROPEAN JOURNAL OF OPHTHALMOLOGY
Journal
  • Dati Generali

Dati Generali

URL

http://dx.doi.org/10.5301/ejo.5000108
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 25.12.3.0