abstract:
We tested the performance of two types of silicon photomultipliers, AdvanSiD ASD-NUV-SiPM3S-P and Hamamatsu 3×3 MM-50 UM VUV2, both at room (300 K) and at liquid nitrogen (77 K) temperature: breakdown voltage, quenching resistance, signal shape, gain and dark counts rate have been studied as function of temperature. The response of the devices to ultra-violet light is also studied. © 2014 Elsevier B.V. All rights reserved.
Iris type:
1.1 Articolo in rivista
Keywords:
Cryogenic detectors; Noble liquid detectors; Photon detectors; Instrumentation; Nuclear and High Energy Physics
List of contributors: