Conventional fast neutron flux measurement in the radial piercing channel D of the TRIGA Mark II Reactor, Pavia
Contributo in Atti di convegno
Data di Pubblicazione:
2021
Abstract:
Measurements flux i four positions of a radial piercing channel of TRIGA Mark II nuclear reactor of Pavia was performed by means of a bare irradiation method and a Monte Carlo simulation both relying on Ni monitors. Reaction rates per target nucleus of Ni, obtained from
measurement and simulation, were compared in order to verify the accuracy of the simulations.
A satisfactory agreement was observed since the results were compatible within the stated uncertainties with exception of values related to the position closest to the reactor core, where a discrepancy at ten percent level was highlighted. Consequently, the Monte Carlo code used for the simulation was considered to be validated and thus, intended to be used in the forthcoming
structural modifications of the channel D which include neutron shielding and thermal neutron
filter.
Tipologia CRIS:
4.1 Contributo in Atti di convegno
Keywords:
Measurements flux, TRIGA Mark II nuclear reactor, Monte Carlo simulation, Ni monitor.
Elenco autori:
Di Luzio, M.; D'Agostino, G.; Fatemi, S.; Smilgys, B.; Salvini, A.; Oddone, M.; Altieri, S.; Prata, M.
Link alla scheda completa:
Titolo del libro:
NENE 2020 29th International Conference Nuclear Energy for New Europe 2020