Skip to Main Content (Press Enter)

Logo UNIPV
  • ×
  • Home
  • Degrees
  • Courses
  • Jobs
  • People
  • Outputs
  • Organizations

UNIFIND
Logo UNIPV

|

UNIFIND

unipv.it
  • ×
  • Home
  • Degrees
  • Courses
  • Jobs
  • People
  • Outputs
  • Organizations
  1. Outputs

Energy Performance Indicators for Air-Conditioned Museums in Tropical Climates

Academic Article
Publication Date:
2024
abstract:
The energy design of museums in developing countries is a subject that has been poorly studied, despite its significant implications for heritage preservation, human comfort, energy efficiency, and environmental sustainability. This study introduces a comprehensive framework of Energy Performance Indicators tailored to air-conditioned museums in tropical regions, which represent the most prevalent museum type. These indicators are particularly important as international standards may not be applicable in these contexts. A comprehensive review of the factors and their design implications is provided at the building, system, and component levels. Efficient integration of lighting and air conditioning systems can optimize energy use while maintaining appropriate conditions for both artefact preservation and visitor comfort. Parameters such as average illuminance, uniformity of lighting, lighting power density and lighting energy use intensity are critical in balancing visual quality and energy efficiency. Recommended values and strategies, such as the use of LED lighting and daylight harvesting, help to minimize energy consumption. In addition, parameters such as power density and energy use intensity of air conditioning systems are essential for assessing their efficiency. Techniques such as the integration of solar-assisted, optimized performance indices can effectively reduce energy consumption. Synthetic indicators for assessing lighting quality and overall energy performance are (i) Average Illuminance Ratio, which assesses the adequacy of lighting in a space by comparing the average measured illuminance with the recommended illuminance levels for that space, and (ii) Energy Use Intensity, which represents the total annual energy consumption per unit area of conditioned space. By adopting these indicators, tropical museums can advance energy efficiency and broader sustainability objectives, taking a significant step towards a more energy-conscious and sustainable future.
Iris type:
1.1 Articolo in rivista
List of contributors:
Lucchi, Elena
Authors of the University:
LUCCHI ELENA
Handle:
https://iris.unipv.it/handle/11571/1508473
Published in:
BUILDINGS
Journal
  • Use of cookies

Powered by VIVO | Designed by Cineca | 26.4.0.0