Skip to Main Content (Press Enter)

Logo UNIPV
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture

UNIFIND
Logo UNIPV

|

UNIFIND

unipv.it
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture
  1. Pubblicazioni

Vickers micro-hardness of new restorative CAD/CAM dental materials: Evaluation and comparison after exposure to acidic drink

Articolo
Data di Pubblicazione:
2019
Abstract:
CAD/CAM (computer-aided design/computer-aided manufacturing) for indirect restorative materials has been recently introduced in dentistry. The purpose of this study was to evaluate the change of the surface micro-hardness of different restorative CAD/CAM materials after exposure to a carbonated acidic drink (Coca-Cola, Coca-Cola Company, Milan, Italy). One hundred and eighty specimens of identical size (2 mm thickness) were obtained by sectioning each tested CAD/CAM block of four materials: a hybrid ceramic (CERASMART™, GC Corporation, Tokyo, Japan), a resin nano ceramic (Lava™ Ultimate, 3M, Monrovia, CA, USA), a nanohybrid composite (Grandio blocs, VOCO GmbH, Cuxhaven, Germany), and a zirconia-reinforced lithium silicate glass ceramic (VITA SUPRINITY® PC; VITA Zahnfabrik, Bad Sackingen, Germany). Forty-five specimens of each material were tested. Micro-hardness was measured at baseline, after 7 days and after 28 days. The data were analyzed. The micro-hardness of each material varied significantly after immersion in Coca-Cola. The nanohybrid composite had a high initial micro-hardness and the greatest percentage loss after acid exposure. The hybrid ceramic and the resin nano ceramic had similar percentage losses of micro-hardness values even if the second material had higher initial values. The zirconia-reinforced lithium silicate glass ceramic had the highest baseline values and the lowest percentage loss of micro-hardness. The different CAD/CAM materials presented different micro-hardness values before and after acid exposure.
Tipologia CRIS:
1.1 Articolo in rivista
Keywords:
Acidic drink; CAD/CAM; Ceramic; Composite resins; Dentistry; Vickers micro-hardness
Elenco autori:
Colombo, M.; Poggio, C.; Lasagna, A.; Chiesa, M.; Scribante, A.
Autori di Ateneo:
COLOMBO MARCO
SCRIBANTE ANDREA
Link alla scheda completa:
https://iris.unipv.it/handle/11571/1310627
Pubblicato in:
MATERIALS
Journal
  • Dati Generali

Dati Generali

URL

https://res.mdpi.com/materials/materials-12-01246/article_deploy/materials-12-01246.pdf?filename=&attachment=1
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 26.1.3.0